2016-12-20M.Montani, F.PiergiovanniFibers for t_venting_chamber250mm_1We link to this log the fiber used in the testFiber20161129_1Delete
2016-12-20M.Montani, F.PiergiovanniFibers for t_venting_chamber250mm_1We link to this log the fiber used in the testFiber20161129_2Delete
2016-12-20M.Montani, F.PiergiovanniFibers for t_venting_chamber250mm_1We link to this log the fiber used in the testFiber20161129_3Delete
2016-12-20M.Montani, F.PiergiovanniFibers for t_venting_chamber250mm_1We link to this log the fiber used in the testStaticTestt_venting_chamber250mm_1Delete
2017-02-21M.MontaniHigh Speed Camera Test (Photron)On february the 21st we performed a test on an High Speed Camera from Photron. The model used is the AX200, but we used it with the same frame rate of the AX50. We did 4 breaking tests with 4 fibers. TEST01: - fiber with nail head 20170111_01 TEST02: - fiber with nail head 20161027_03 (broken at 50kg) TEST03 - fiber with old anchors 20160428_3 (broken at 43kg) TEST04 - fiber with nail head 20170111_2 touched in the middle with hands. The optic used was 28mm, and the light was provided by two powerful LED headlamps. The tests confirmed that the camera is suitable for our aims.Fiber20170111_1Delete
2017-02-21M.MontaniHigh Speed Camera Test (Photron)On february the 21st we performed a test on an High Speed Camera from Photron. The model used is the AX200, but we used it with the same frame rate of the AX50. We did 4 breaking tests with 4 fibers. TEST01: - fiber with nail head 20170111_01 TEST02: - fiber with nail head 20161027_03 (broken at 50kg) TEST03 - fiber with old anchors 20160428_3 (broken at 43kg) TEST04 - fiber with nail head 20170111_2 touched in the middle with hands. The optic used was 28mm, and the light was provided by two powerful LED headlamps. The tests confirmed that the camera is suitable for our aims.Fiber20161027_3 Delete
2017-02-21M.MontaniHigh Speed Camera Test (Photron)On february the 21st we performed a test on an High Speed Camera from Photron. The model used is the AX200, but we used it with the same frame rate of the AX50. We did 4 breaking tests with 4 fibers. TEST01: - fiber with nail head 20170111_01 TEST02: - fiber with nail head 20161027_03 (broken at 50kg) TEST03 - fiber with old anchors 20160428_3 (broken at 43kg) TEST04 - fiber with nail head 20170111_2 touched in the middle with hands. The optic used was 28mm, and the light was provided by two powerful LED headlamps. The tests confirmed that the camera is suitable for our aims.Fiber20160428_3Delete
2017-02-21M.MontaniHigh Speed Camera Test (Photron)On february the 21st we performed a test on an High Speed Camera from Photron. The model used is the AX200, but we used it with the same frame rate of the AX50. We did 4 breaking tests with 4 fibers. TEST01: - fiber with nail head 20170111_01 TEST02: - fiber with nail head 20161027_03 (broken at 50kg) TEST03 - fiber with old anchors 20160428_3 (broken at 43kg) TEST04 - fiber with nail head 20170111_2 touched in the middle with hands. The optic used was 28mm, and the light was provided by two powerful LED headlamps. The tests confirmed that the camera is suitable for our aims.Fiber20170111_2Delete
2017-05-08M.montanibroken fiber after testsThe fiber was broken after tests (VAC team or high speed camera). After annealing we use the same nail head for new fiber (20170508_x)Fiber20160428_3Delete
2017-05-08M.montanibroken fiber after testsThe fiber was broken after tests (VAC team or high speed camera). After annealing we use the same nail head for new fiber (20170508_x)Fiber20161115_1Delete
2021-04-16Matteo Montanicalibration for length machine in UrbinoThe fiber 20172311_3 was used for calibration of the length machine in Urbino. Was measured but it brake at about 6kg. The anchor are safeDelete