T01_01 | 0000-00-00 | 34.4 | 0 | broken | broken | T01_01 | we load with the machine but due to a saturation problem we cannot see the effective load over 21 kg, so we decide to test with the 50 kg, reading directly the loading cell. Everything breaks at 34.4 kg. Because of the previous attempt, the fibre was surely “aged”. | Delete |
T01_02 | 0000-00-00 | 32.7 | 0 | intact | intact | T01_02 | same parameters as before. Breaks at 32.7 kg. We suspect the breaking being due to the nail heads: the lower one is broken close to the head, the upper one is almost intact. It seems that short fibre’s segments are on the floor. | Delete |
T07_01 | 2017-03-20 | 50 | | Intact | Intact | T07_01 | One nail head has slipped away by an O-ring breaking at 50kg | Delete |
T08_01 | 2017-03-21 | 74 | | Intact | Intact | T08_01 | Loaded with 70/75 kg for 30 min (survived) | Delete |